Customize Product

MB2 Mini-Batcher Batch Controller – KEP

Description

The Mini-Batcher is a 6 digit totalizer and 4.5 digit rate meter with two relay outputs. One output is dedicated to the batch amount (Preset A), the other can be activated for Prewarn or Batch/Grand Total. The unit can count up to the preset (reset to 0) or down from the preset (set to preset). Start, Stop and Reset functions can be activated from the front panel or remote inputs.. An analog output (assignable for Rate or Batch Amount) is available for data logging. Several units can communicate to a host computer on a single RS232 or RS422 loop.

Up to 247 units can communicate to a host computer using Modbus RTU protocol. Alternately, an analog output (assignable for Rate or Batch Amount) can be ordered for data logging.

  • Display Rate, Batch Size and Number of Batches or Grand Total
  • 5 Digit Scaling Factor
  • Pulse Input
  • 2 Relay Outputs
  • Analog Output or Serial/Modbus Options
  • NEMA 4X / IP65 Front Panel

 

Catalog-Page-9                        KEP-MB2-MINI-Batcher

This product is currently out of stock and unavailable.

Show Advanced Filters

products found
Item # Count Inputs Operating Voltage Options
KE/MB2A314-30 VDC or 0-1VDC pulse, 10kHz max.110 VAC ±15% or 12-15 VDCRS232 Comm., KEP protocol
KE/MB2A324-30 VDC or 0-1VDC pulse, 10kHz max.110 VAC ±15% or 12-15 VDCRS422 Comm., KEP protocol
KE/MB2A334-30 VDC or 0-1VDC pulse, 10kHz max.110 VAC ±15% or 12-15 VDCRS232, Modbus RTU
KE/MB2A344-30 VDC or 0-1VDC pulse, 10kHz max.110 VAC ±15% or 12-15 VDCRS422/RS485, Modbus RTU
KE/MB2A3A4-30 VDC or 0-1VDC pulse, 10kHz max.110 VAC ±15% or 12-15 VDCAnalog Output (4-20/0-20 mA)
KE/MB2A3M130mV mag. pickup, 5kHz max.110 VAC ±15% or 12-15 VDCRS232 Comm., KEP protocol
KE/MB2A3M230mV mag. pickup, 5kHz max.110 VAC ±15% or 12-15 VDCRS422 Comm., KEP protocol
KE/MB2A3M330mV mag. pickup, 5kHz max.110 VAC ±15% or 12-15 VDCRS232, Modbus RTU
KE/MB2A3M430mV mag. pickup, 5kHz max.110 VAC ±15% or 12-15 VDCRS422/RS485, Modbus RTU
KE/MB2A3MA30mV mag. pickup, 5kHz max.110 VAC ±15% or 12-15 VDCAnalog Output (4-20/0-20 mA)
KE/MB2B314-30 VDC or 0-1VDC pulse, 10kHz max.220 VAC ±15% or 12-15 VDCRS232 Comm., KEP protocol
KE/MB2B324-30 VDC or 0-1VDC pulse, 10kHz max.220 VAC ±15% or 12-15 VDCRS422 Comm., KEP protocol
KE/MB2B334-30 VDC or 0-1VDC pulse, 10kHz max.220 VAC ±15% or 12-15 VDCRS232, Modbus RTU
KE/MB2B344-30 VDC or 0-1VDC pulse, 10kHz max.220 VAC ±15% or 12-15 VDCRS422/RS485, Modbus RTU
KE/MB2B3A4-30 VDC or 0-1VDC pulse, 10kHz max.220 VAC ±15% or 12-15 VDCAnalog Output (4-20/0-20 mA)
KE/MB2B3M130mV mag. pickup, 5kHz max.220 VAC ±15% or 12-15 VDCRS232 Comm., KEP protocol
KE/MB2B3M230mV mag. pickup, 5kHz max.220 VAC ±15% or 12-15 VDCRS422 Comm., KEP protocol
KE/MB2B3M330mV mag. pickup, 5kHz max.220 VAC ±15% or 12-15 VDCRS232, Modbus RTU
KE/MB2B3M430mV mag. pickup, 5kHz max.220 VAC ±15% or 12-15 VDCRS422/RS485, Modbus RTU
KE/MB2B3MA30mV mag. pickup, 5kHz max.220 VAC ±15% or 12-15 VDCAnalog Output (4-20/0-20 mA)
KE/MB2C314-30 VDC or 0-1VDC pulse, 10kHz max.24 VAC ±15% or 12-15 VDCRS232 Comm., KEP protocol
KE/MB2C324-30 VDC or 0-1VDC pulse, 10kHz max.24 VAC ±15% or 12-15 VDCRS422 Comm., KEP protocol
KE/MB2C334-30 VDC or 0-1VDC pulse, 10kHz max.24 VAC ±15% or 12-15 VDCRS232, Modbus RTU
KE/MB2C344-30 VDC or 0-1VDC pulse, 10kHz max.24 VAC ±15% or 12-15 VDCRS422/RS485, Modbus RTU
KE/MB2C3A4-30 VDC or 0-1VDC pulse, 10kHz max.24 VAC ±15% or 12-15 VDCAnalog Output (4-20/0-20 mA)
KE/MB2C3M130mV mag. pickup, 5kHz max.24 VAC ±15% or 12-15 VDCRS232 Comm., KEP protocol
KE/MB2C3M230mV mag. pickup, 5kHz max.24 VAC ±15% or 12-15 VDCRS422 Comm., KEP protocol
KE/MB2C3M330mV mag. pickup, 5kHz max.24 VAC ±15% or 12-15 VDCRS232, Modbus RTU
KE/MB2C3M430mV mag. pickup, 5kHz max.24 VAC ±15% or 12-15 VDCRS422/RS485, Modbus RTU
KE/MB2C3MA30mV mag. pickup, 5kHz max.24 VAC ±15% or 12-15 VDCAnalog Output (4-20/0-20 mA)
Sorry, no products were found fitting that criteria. Please widen your search or reset item filters now