  • Wide Choice of Inputs:
  • Volts AC/DC, Amps AC/DC, Process V/mA, Strain, Frequency, RTD,  Potentiometer
  • Variable Brightness I/O Status LEDs
  • 1200V Isolation
  • Output Test Button
  • UL & cUL Recognized
  • Lifetime Warranty

Catalog-Page-81a                                 API-brochure

For factory set models, specify input and output range when ordering.

Show Advanced Filters

products found
Item # Function Selectable Range Input Range Output Range
APD 4300TransmitterFactory0-100 mVDC to 0-300 VDC, ±100 mVDC to ±10 VDC, 0-1 mADC to 0-900 mADC0-1 VDC to 0-10 VDC ±1 VDC to ±10 VDC (10mA max) 0-1 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 1800AlarmFactoryAny full-range potentiometer from 0-100ohm to 0-1Mohm2 DPST relays, 8A, 1 HI setpoint
APD 1830AlarmFactoryAny full-range potentiometer from 0-100ohm to 0-1Mohm2 DPST relays, 8A, 2 setpoints, band alarm
APD HV-DCTransmitterField8 switch selectable, 0-100 VDC to 0-1200VDC or custom to 2000VDC18 switch selectable, 0-1 VDC to 0-10 VDC ±5 VDC to ±10 VDC (10mA max) 0-2 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4930DC to DC Signal Splitter Isolater/Transmitter0-10mv to 100V, ±50mV to ±10V, 0-1ma to 0-50ma, 4-20mA0-1V to 0-10V ±1V to ±10V 0-1mA to 20mA 4-20mA
APD 4380TransmitterField47 switch selectable, 0-10 mVDC to 0-130 VDC, ±5 mVDC to ±65 VDC, 0-200 uADC to 0-50 mADC18 switch selectable, 0-1 VDC to 0-10 VDC ±5 VDC to ±10 VDC (10mA max) 0-2 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4008TransmitterFieldAny full-range potentiometer from 0-100ohm to 0-1Mohm, 55 switch selectable, 0-10% to 0-100%18 switch selectable, 0-1 VDC to 0-10 VDC ±5 VDC to ±10 VDC (10mA max) 0-2 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 6380TransmitterField28 switch selectable: 0-40 mVAC to 0-300 VAC TRMS, 22 switch selectable: 0-4 mAAC to 0-200 mAAC TRMS18 switch selectable, 0-1 VDC to 0-10 VDC ±5 VDC to ±10 VDC (10mA max) 0-2 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 7580TransmitterField30 switch selectable, 0-100 Hz to 0-30 kHz,100 mVrms to 150Vrms18 switch selectable, 0-1 VDC to 0-10 VDC ±5 VDC to ±10 VDC (10mA max) 0-2 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4059TransmitterField13 switch selectable: 5 mV to 400 mV; 1-10 VDC exc. For 1-4 350ohm bridge or strain gauge sensors, 120 mA max.18 switch selectable, 0-1 VDC to 0-10 VDC ±5 VDC to ±10 VDC (10mA max) 0-2 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 6010TransmitterFactory0-40 mVAC to 0-300 VAC TRMS, 0-1 mAAC to 0-1000 mAAC TRMS0-1 VDC to 0-10 VDC ±1 VDC to ±10 VDC (10mA max) 0-1 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4001TransmitterFactoryRTD (10-2000ohm), or Thermistor (2k-20kohm), (specify type, curve, °C or °F & range)0-1 VDC to 0-10 VDC ±1 VDC to ±10 VDC (10mA max) 0-1 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 1090AlarmField24 switch selectable, 0-50 mVDC to 0-10 VDC, ±5 VDC to ±10 VDC, 0-1 mADC to 0-20 mADC2 DPST relays, 8A, 2 setpoint
APD 7010TransmitterFactory0-25 Hz to 0-20 kHz, 100 mVrms to 150Vrms0-1 VDC to 0-10 VDC ±1 VDC to ±10 VDC (10mA max) 0-1 mADC to 0-20 mADC, 4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 1020AlarmFactory0-100 mVDC to 0-300 VDC, ±100 mVDC to ±10 VDC, 0-1 mADC to 0-900 mADC2 DPST relays, 8A, 2 setpoints HI/LO
APD 1080AlarmField24 switch selectable, 0-50 mVDC to 0-10 VDC, ±5 VDC to ±10 VDC, 0-1 mADC to 0-20 mADC2 DPST relays, 8A, 1 setpoint
APD 1000AlarmFactory0-100 mVDC to 0-300 VDC, ±100 mVDC to ±10 VDC, 0-1 mADC to 0-900 mADC2 DPST relays, 8A, 1 HI setpoint
APD 1600AlarmFactory0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-1000 mAAC2 DPST relays, 8A, 1 HI setpoint
APD 1630AlarmFactory0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-1000 mAAC2 DPST relays, 8A, 2 setpoints, band alarm
APD 1620AlarmFactory0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-1000 mAAC2 DPST relays, 8A, 2 setpoints HI/LO
APD 1430AlarmFactoryRTD (10-2000ohm), or Thermistor (2k-20kohm), (specify type, curve, °C or °F & range)2 DPST relays, 8A, 2 setpoints, band alarm
APD 1420AlarmFactoryRTD (10-2000ohm), or Thermistor (2k-20kohm), (specify type, curve, °C or °F & range)2 DPST relays, 8A, 2 setpoints HI/LO
APD 1400AlarmFactoryRTD (10-2000ohm), or Thermistor (2k-20kohm), (specify type, curve, °C or °F & range)2 DPST relays, 8A, 1 HI setpoint
APD 1030AlarmFactory0-100 mVDC to 0-300 VDC, 0-1 mADC to 0-20 mADC, 4-20 mADC2 DPST relays, 8A, 2 setpoints, band alarm
APD 1700AlarmFactory0-10 Hz to 0-20 kHz, 100 mVrms to 150Vrms2 DPST relays, 8A, 1 HI setpoint
APD 1720AlarmFactory0-10 Hz to 0-20 kHz, 100 mVrms to 150Vrms2 DPST relays, 8A, 2 setpoints HI/LO
APD 1730AlarmFactory0-10 Hz to 0-20 kHz, 100 mVrms to 150Vrms2 DPST relays, 8A, 2 setpoints, band alarm
APD 1820AlarmFactoryAny full-range potentiometer from 0-100ohm to 0-1Mohm2 DPST relays, 8A, 2 setpoints HI/LO
APD 1530AlarmFactory100ohm to 10kohm bridge, strain gauge, load cell: 5-2000 mv; 1-10VDC excitation, 30mA max Specify excitation voltage, mV range and mV/V2 DPST relays, 8A, 2 setpoints, band alarm
APD 1520AlarmFactory100ohm to 10kohm bridge, strain gauge, load cell: 5-2000 mv; 1-10VDC excitation, 30mA max Specify excitation voltage, mV range and mV/V2 DPST relays, 8A, 2 setpoints HI/LO
APD 1500AlarmFactory100ohm to 10kohm bridge, strain gauge, load cell: 5-2000 mv; 1-10VDC excitation, 30mA max Specify excitation voltage, mV range and mV/V2 DPST relays, 8A, 1 HI setpoint
Sorry, no products were found fitting that criteria. Please widen your search or reset item filters now