Acuvim II Power Transducers – Accuenergy
Description
The Acuvim II series multifunction power and energy meters are also available as DIN-rail mount transducers without integral display. These transducers may be used as data gathering devices for intelligent power distribution systems or plant automation systems. All monitored data is available via a digital RS485 communication port running Modbus RTU and DNP 3.0 protocols. A second communication port is available as an add-on module with Ethernet Modbus TCP and DNP3.0 over IP. A remote display can be ordered for separate viewing or as a setup aide.
· Revenue Grade with Data Logging (0.2 Class)
· Waveform Capture
· Level 2 DNP3 standard, IEC61850 available
· 8GB Datalogging and event storage
· COMtrade Waveform format
· Free Cloud Metering Data Storage + Analytics
Item # | Description | Current Input | Power |
---|---|---|---|
AXM-485 | Second RS485 Modbus RTU | --- | --- |
AcuvimIIW-M-RCT-P1 | Transducer with datalogging, waveform capture & PQ event logging | AcuCT-Flex | 100-415VAC (50-60Hz)/100-300VDC |
AcuvimIIR-M-RCT-P1 | Transducer with datalogging & time of use | AcuCT-Flex | 100-415VAC (50-60Hz)/100-300VDC |
AcuvimIIE-M-RCT-P1 | Transducer with datalogging | AcuCT-Flex | 100-415VAC (50-60Hz)/100-300VDC |
AXM-WEB2 | Dual Ethernet Modbus TCP, DNP3 & IEC61850 | --- | --- |
AcuvimIIR-M-mA-P1 | Transducer with datalogging & time of use | 80mA/100mA/200ma (field selectable) | 100-415VAC (50-60Hz)/100-300VDC |
AcuvimIIW-M-mA-P1 | Transducer with datalogging, waveform capture & PQ event logging | 80mA/100mA/200ma (field selectable) | 100-415VAC (50-60Hz)/100-300VDC |
AcuvimII-M-333-P1 | Basic transducer | 333mV | 100-415VAC (50-60Hz)/100-300VDC |
AcuvimIIE-M-333-P1 | Transducer with datalogging | 333mV | 100-415VAC (50-60Hz)/100-300VDC |
AcuvimIIR-M-333-P1 | Transducer with datalogging & time of use | 333mV | 100-415VAC (50-60Hz)/100-300VDC |
AcuvimIIW-M-333-P1 | Transducer with datalogging, waveform capture & PQ event logging | 333mV | 100-415VAC (50-60Hz)/100-300VDC |
AcuvimII-M-RCT-P1 | Basic transducer | AcuCT-Flex | 100-415VAC (50-60Hz)/100-300VDC |
AXM-WEB-PUSH | Ethernet Modbus TCP, DNP3.0 over IP | --- | --- |
REM-DS2 | Remote Display | --- | --- |
AcuvimIIW-M-RCT-P2 | Transducer with datalogging, waveform capture & PQ event logging | AcuCT-Flex | 20-60VDC |
AcuvimIIR-M-RCT-P2 | Transducer with datalogging & time of use | AcuCT-Flex | 20-60VDC |
AcuvimIIE-M-RCT-P2 | Transducer with datalogging | AcuCT-Flex | 20-60VDC |
AcuvimII-M-RCT-P2 | Basic transducer | AcuCT-Flex | 20-60VDC |
AcuvimIIW-M-333-P2 | Transducer with datalogging, waveform capture & PQ event logging | 333mV | 20-60VDC |
AcuvimIIR-M-333-P2 | Transducer with datalogging & time of use | 333mV | 20-60VDC |
AcuvimIIE-M-333-P2 | Transducer with datalogging | 333mV | 20-60VDC |
AcuvimII-M-333-P2 | Basic transducer | 333mV | 20-60VDC |
AcuvimIIW-M-mA-P2 | Transducer with datalogging, waveform capture & PQ event logging | 80mA/100mA/200ma (field selectable) | 20-60VDC |
AcuvimIIR-M-mA-P2 | Transducer with datalogging & time of use | 80mA/100mA/200ma (field selectable) | 20-60VDC |
AcuvimIIE-M-mA-P2 | Transducer with datalogging | 80mA/100mA/200ma (field selectable) | 20-60VDC |
AcuvimII-M-mA-P2 | Basic transducer | 80mA/100mA/200ma (field selectable) | 20-60VDC |
AcuvimIIW-M-5A-P2 | Transducer with datalogging, waveform capture & PQ event logging | 5A/1A (field selectable) | 20-60VDC |
AcuvimIIR-M-5A-P2 | Transducer with datalogging & time of use | 5A/1A (field selectable) | 20-60VDC |
AcuvimIIE-M-5A-P2 | Transducer with datalogging | 5A/1A (field selectable) | 20-60VDC |
AcuvimII-M-5A-P2 | Basic transducer | 5A/1A (field selectable) | 20-60VDC |
AccuvimII-M-5A-P1 | Basic transducer | 5A/1A (field selectable) | 100-415VAC (50-60Hz)/100-300VDC |
AccuvimIIR-M-5A-P1 | Transducer with datalogging | 5A/1A (field selectable) | 100-415VAC (50-60Hz)/100-300VDC |
AccuvimIIE-M-5A-P1 | Transducer with datalogging & time of use | 5A/1A (field selectable) | 100-415VAC (50-60Hz)/100-300VDC |
AccuvimIIW-M-5A-P1 | Transducer with datalogging, waveform capture & PQ event logging | 5A/1A (field selectable) | 100-415VAC (50-60Hz)/100-300VDC |
AccuvimII-M-mA-P1 | Basic transducer | 80mA/100mA/200ma (field selectable) | 100-415VAC (50-60Hz)/100-300VDC |
AccuvimIIR-M-mA-P1 | Transducer with datalogging | 80mA/100mA/200ma (field selectable) | 100-415VAC (50-60Hz)/100-300VDC |