Item #W4-14EW-EW00, 196 Series Optical Meter Relays - LFE

The 195 Series and 196 Series Meter-Relays contain an exclusive light-sensitive transistor switch that provides the ultimate in control simplicity and reliability. This switch controls the load relays. There are no pointer contacts or mechanical interference in the meter mechanism. The controllers are supplied with a plug-in control module that mounts directly on the rear of the Meter-Relay or may be remotely mounted with an accessory cable.

Effects of shock, vibration, humidity and temperature are equal to or better than ANSI C39.1- 1981. Safety (dielectric test, leakage and other hazards): instruments are equal to or better than ANSI C39.5-1974.
The above tolerance limits apply to the standard ranges listed in this bulletin. Special instruments may vary from these limits. Rated circuit to ground voltage=800 RMS (1100 Peak).

  • Modern Rectangular Appearance
  • Plug-In Control Module
  • Proven Optical Setpoints
  • Limit Lights & Manual Reset Switches Optional (Model 1967)

Order by Description
DC Milliamperes – Range: 0-1 to 0-800
DC Amperes – Range: 0-1 to 0-50
DC Volts 1000 Ohms/Volt- Range: 0-1 to 0-600
AC Volts 1000 Ohms/Volt – Range: 0-10 to 0-300

On/Off Control, Single High Setpoint

Catalog Page 079A-B              195-196-CatPage

Request a Quote

Specifications

Ranges
AC
Size (in)
4.5
Type
Micromperes
Range
0-800
Setpoints
Single Hi
Height (in)
3.756
Width (in)
4.632
Depth (in)
2.897
Depth Behind Panel (in)
6.745
Accuracy
±3%
Zero Balance
±1%
Repeatability
±2%
Overload
Continuous: 150%
1 Second: 150%
Overshoot
0.2
Response Time (s)
3
Center Frequency (Hz)
60